- Home
- ยป
- Our Product Range
- »
- Test Chambers
Test Chambers
Muffle Furnace
Minimum Order Quantity: 1 Unit
Melting Material | any |
Material Loading Capacity (T) | ask |
Power Source | Electric |
Type Of Furnace | Fix |
Rated Power (KW) | 1.5 |
Input Voltage (V) | 230v |
Furnace Voltage (V) | 230v |
Voltage | 230 v |
Melting Time | depends on sample |
Max OperatingTemperature | 1150 C |
Muffle Furnace
• Light weight and faster heating equipment.• Most Useful For Ashing, Fasions, Igniting And Heat Trating Of Small Parts In Chemical, Industrial Fields , Colleges.• Outer body made up of heavy gauge G.I. duly powder coated inner muffle with high temperature insulating material.• Maximum temperatures 11500C and working temperature 11000C.• Digital temperature controller cum indicator used in controlling the temperature.• Heating elements made of kanthal wire would extremely on the muffle.• Control panel fitted on top of the units with indicating lamps and switches.• A uniform heat distribution through all 4 side with kanthal wire.• A special solid state silver fuse for defense to elements in case of over heating..• Operates on 230 volts A.C only.• Available in various sizes.
Humidity Chamber
Minimum Order Quantity: 1 Unit
Country of Origin | Made in India |
Temp. Range | Temp.10 Degree C to 60 Degree C |
Humidity Range | 40% RH to 85% |
Dimensions | contact HPFS |
Color | contact HPFS |
Controller | HPFS |
HUMIDITY CONTROL OVEN (Cooling)
Also know as Environmental Test chamber or Stability chamber-Double Walled –Inner SS-Outer MS-3”Gap Glass Wool insulation:
* Full length inner acrylic door for clear inner view-outer metal door with magnetic gaskets & lock.
* Forced air circulation for uniform temperature throughout the chamber.
* Digital display preset electronic digital temperature controller cum indicator but with cooling system by means of hermetically sealed Compressor Unit coupled with evaporation Coil and condenser.
* Temp. Range 10°C to 60°C ±1°C:
* Humidity Range 40% RH to 85% RH ±3% RH
Inner working size of Humidity Oven Capacity |
Inner Chamber D x W x H (cms) |
No. of Shelves |
3 CFT(90L) |
45x45x50 |
2 |
6 CFT (170L) |
50x50x70 |
2 |
Sensor for RH Upto 95% RH extra cost |
FOR HUMIDITY OVEN STABILIZER IS MUST (Cost Extra) |
Voltage Stabilizer for 90ltr & 170ltr |
Voltage Stabilizer for 280ltr & 320ltr |
NOTE : Above Given Prices are for refernce only, kindly ask for quotation based on your specification and application.
Additional Information:
- Production Capacity: as per your requirement
- Delivery Time: within 4 to 8 weeks or earlier
- Packaging Details: kindly contact HPFS
Stability Chamber (gmp Model)
Usage/Application | Stability Chamber |
Chamber | Stability |
Cooling | With Condenser |
Temperature Range | 10 degree C to 60 degree C |
Humidity Range | 35% to 98% RH+-3% RH |
Phase | 3 |
Voltage | 230 Volts 50 H2 |
Material | Refer specification |
Capacity | As per your application |
STABILITY CHAMBER (GMP MODEL)
* Double Walled construction Outer S.S.304 & Inner S.S.316
* PUF Insulation between Two Walled
* Temp. Range 10 ??C to 60 ??C with Accuracy ±1??C
* Humidity Range: 35% to 98% RH±3% RH
* Positive Vertical Circulation by Motorized Blower for Uniform Temp.
* Temp. Controlled By PID Controller
* Low Pressure Boiler at Bottom to generate Steam for chamber humidification
* The chamber is provided with modular removable shelves made of S. S. for comp. Flexibility.
* A Key lockable insulate door having positive door Gasket seals door perfectly.
* Inner Acrylic Door View sample.
* It works on 230 Volts 50 H2.
Inner working size of Stability Chamber Capacity |
Inner Chamber D x W x H (cms) |
No. of Shelves |
3 cft (90L) |
45x45x50 |
2 |
6 cft (170L) |
50x50x70 |
2 |
FOR HUMIDITY OVEN STABILIZER IS MUST (Cost Extra) |
Voltage Stabilizer for 90ltr & 170ltr |
Voltage Stabilizer for 280ltr & 320ltr |
NOTE : IQ/OQ/PQ DOCUMENT CHARGES WILL BE EXTRA AS APPLICABLE
ON SITE VALIDATION CHARGES WILL BE EXTRA AS APPLICABLE
NOTE : Prices are for reference only, kindly send your specification and application for prices.