- Home
- ยป
- Our Product Range
- »
- Coating Thickness Guage
Coating Thickness Guage
Coating Thickness Gauge Carsys
Minimum Order Quantity: 100 Piece
Product Brochure
Brand | Carsys |
Model Name/Number | DPM 816 PRO |
Net weight (without battery) | 50 g |
Display Size | 20x33 mm |
Measurement Duration | 0.5-1 sec. |
Operating Temperature (Humidity Not Higher Than 70%) | -25 to 40 Degree C |
Permissible error (700-3000 um) | +- 1% + 10 um |
Permissible error (0-699 um) | +- 1% + 1 um |
Measurement Precision | 1 um / 0.01 mm / 0.1 mil |
Presenting our device for measuring coating thickness (any non-metallic coating, for example paint, spackling paste) applied on a metal base (steel, iron, galvanised steel, aluminium alloys, zinc, etc.)Thickness Gauge
Applications:
The coating thickness gauge can be used for measuring paint thickness,
determine the condition of the car body, in various manufacturing quality controls.
Here are more sample use cases:
Buying a new or used car.
Dent repair on the car body without painting.
Checking the paint coat thickness during polishing.
Colouring of metal parts or the car body with control of coating thickness.
Car condition assessment for insurance companies and those specialising in car selection.
Control for applying fireproof and protective coatings.
Advantages of the Thickness Gauge:
Accurate and stable measurements.
Thickness measurement on ferrous and non-ferrous metal bases.
Thickness measurement range 0-3 mm (0-3000 μm).
Automatic determination of metal base (ferrous or non-ferrous).
Displays result in mm, μm, and thousandths of an inch (mil).
Thickness measurement on galvanised steel parts.
Allows for custom calibration for specific metals.
Fast user calibration using one or two points of reference.
5 modes of operation, for various usage conditions.
Backlit display for measuring thickness in poor lighting.
Automatic detection when the measurement starts.
Registered trademark and patent.
Three-year warranty.
Concrete Coating Thickness Gauge
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Elcometer |
Model Name/Number | Elcometer 500 C |
Power Supply | 2 x AA batteries (rechargeable batteries can be used) |
Operating Temperature | -10 to 50 Degree C (14 to 122 Degree F) |
Accuracy | 10 micron |
Battery Life | Alkaline: Approximately 15 hours Lithium: Approximately 28 hours |
Display Type | Digital |
Gauge Dimensions | 141 x 73 x 37mm (5.55 x 2.87 x 1.46") without transducer |
Gauge Weight | 161g (5.68oz) including batteries, without transducer |
Scale C1
T500-C1
Elcometer 500 Scale C1 Probe
Certificate
Range1 : 150 - 2,500μm (6 - 98mils)
Accuracy2 : ±2% or ±10μm (±2% or ±0.4mil)
Resolution: Low: 10μm, 0.01mm, 1mil or 0.001” High: 1μm, 0.001mm, 0.1mil or 0.0001”
Scale C2
T500-C2
Elcometer 500 Scale C2 Probe
Certificate
Range1 : 750 - 10,000μm (30 - 390mils) Accuracy2 : ±2% or ±10μm (±2% or ±0.4mil)
Resolution: Low: 10μm, 0.01mm, 1mil or 0.001” High: 1μm, 0.001mm, 0.1mil or 0.0001”
Note:
Please ask quotation for complete Instruments along with Different model.
Digital Coating Thickness Gauge Ec-7
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name / Number | Ec7 |
Resolution | 0.1 um |
Minimum Measurement Area | 10 mm |
Minimum Sample Thickness | 0.3 mm |
Material | Plastic |
Measuring Range | 2000 um |
Brand | HPFS |
Model Name/Number | EC7 |
Accuracy | +-(2.5%+-1)um |
Display Type | 128x128 dots LCD display |
Features and Functions:
Menu interface
LCD can be rotated to be used easily
Red LED alarm indication
LCD shows mean, maximum, minimum and standard deviation
User can set alarm limit
Readings can be stored, recalled and deleted
Easy to do zero calibration and support multi-point calibration
Connect with PC via USB and download readings
Multi-language supported
Up to 5 measurement groups supported
Automatically detect the substrates type(F or N)
Dft Meter Economical Coating Thickness Gauge Ec-9
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name / Number | EC - 9 |
Type | F / NF |
Resolution | 0.1 um |
Minimum Measurement Area | 10 mm |
Minimum Sample Thickness | 0.3 mm |
Material | Plastic |
Measuring Range | 5000 um & 3000 um |
Model Name/Number | EC9 |
Length | 1 m separated probe |
Accuracy | +-2%+-1um |
Display Type | 128x128 dots LCD display |
Sturdy Model, equipped with 1 meter length probe, Auto detection of Fe & Nfe substrates, Range:0-5000 Microns, Supplied with data collection Software & Calibration Certificate.
Features and Functions:
Menu interface
Red LED alarm indication
LCD shows mean, maximum, minimum and standard deviation
Readings can be stored, recalled and deleted
Easy to do zero calibration and support multi-point calibration
Connect with PC via USB and download readings
Multi-language supported
Up to 5 measurement groups supported
Automatically detect the substrates type(F or N)
Qnix 9500 Basic With Integrated Probe Fe 1,2 Mm
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Qnix |
Model Name / Number | 9500 Integral Probe |
Type | F |
Measuring Range | 0 - 2000 um |
Accuracy | 1 % of reading |
Resolution | 0.1 um |
Minimum Measurement Area | 5 mm |
Minimum Sample Thickness | 0.3 mm |
Power Supply | 3 x 1.5V AA batteries |
Main Features of the QNix 9500 series of Coating Thickness Gauges
Most recent factory calibration certificate stored in each probe and downloadable
Measuring ranges: up-to 0–200 mils on FE and 0– 120 mils on NF
Measurement speed – 120+ readings/minute, ideal for production line testing/simply quality control checks out in the field
The intuitive menu navigation for easy handling even by inexpert personnel.
Auto-rotating and adjustable brightness of the display
Ergonomic design, low center of gravity and rubber surface for the perfect handling.
V-groove in the probe holder for positioning on curved parts
Graphic display with flipping measuring presentation view – 0°, 90°, 180°, 270°.
Ready to measure, No need for calibration adjustment for most applications.
Built-in temperature compensation for improved measurement accuracy.
Calibration certificate showing traceability to Physikalisch Technische Bundesanstalt (PTB)- German equivalent to NIST in the US.
Gauge body Built-in Software for statistical evaluation for process control with the QN 9500 PC software.
Define Limits- Pass/Fall warning per RGB LED on probe - Premium & Premium plus only.
Duplex (Fe/NFe) and continuous measuring mode - Premium & Premium plus only.
Multiple calibration adjustments options – Premium & Premium plus only.
Batches for SSPC-PA 2, IMO PSPC, ISO 19840, Australian AS 3894.3 B, Swedish IS 18 41 60 preconfigured – Premium plus only.
Measuring duplex coatings with the QNix 9500 premium and premium plus versions: Paint/hot-dip galvanized coatings on steel are simultaneously measured -using a Dual probe, and their thicknesses are displayed separately.
ALL GAUGES FEATURE........
Tough probes (IP65) & robust housing (IP64)
Waterproof-Solvent, acid, oil-resistant
Designed for rough manufacturing environments
German Engineering
Fields Of Application
Defense, Automotive, commercial & industrial products, medical equipment, shipbuilding, infrastructure, aerospace, offshore, chemical plants, production line testing/simply quality control checks out in the field, etc.
The Trueness Of Measurements:
QNix® 9500 - Accuracy of measurement on Fe substrates related to QNix® reference standards: (1 μm + 2 % of the reading) to 2,0 mm; 3 % of the reading from 2,0 mm
QNix® 9500 - Accuracy of measurement on NFe substrates related to QNix® reference standards: (2 μm + 2 % of the reading) to 2,0 mm; 3 % of the reading from 2,0 mmMeasuring Ranges Of The Available Probes Scope of Supply
• Gauge body with built-in PC software QN9
• Fe- and NFe zero-reference plates and two test foils (shims)
• Certificate of Calibration traceable to PTB (only with integrated
measuring probe)
• Operation/User manual
• USB cable
• 2 Mignon batteries 1,5 V (AA) alkaline
• Plastic case for transportation and storage
Fujitech Digital Film Coating Thickness Gauge F
Minimum Order Quantity: 1 Piece
Model Name / Number | Fujitech Digital Film Coating Thickness Gauge F |
Type | F |
Measuring Range | 0 - 1250 um |
Accuracy | 1 % of reading |
Resolution | 1 um |
Minimum Measurement Area | 10 mm |
Minimum Sample Thickness | 0.3 mm |
Display Type | Digital |
Brand | Fujitech |
Measuring Range | 0~1250 microns |
Accuracy | +/-~3% or 2.5 microns or 0.1 mil |
Size | 145 x 65 x 27 mm |
Operating Temperature | 0 Deg C ~50 Deg C |
Power Supply | 2 x 1.5V AAA battery |
Minimum Order Quantity | 1 |
QNix 9500 Basic Gauge with Separable Probe Fe 1,2 mm
Minimum Order Quantity: 1 Piece
Brand | Qnix |
Model Name / Number | Qnix 9500 with separable Probe |
Type | F |
Measuring Range | 0 - 2000 um |
Accuracy | 1 % of reading |
Resolution | 0.1 um |
Minimum Measurement Area | 5 mm |
Minimum Sample Thickness | 0.2 mm |
Power Supply | 3 x 1.5V AA batteries |
- Most recent factory calibration certificate stored in each probe and downloadable
- Measuring ranges: up-to 0–200 mils on FE and 0– 120 mils on NF
- Measurement speed – 120+ readings/minute, ideal for production line testing/simply quality control checks out in the field
- The intuitive menu navigation for easy handling even by inexpert personnel.
- Auto-rotating and adjustable brightness of the display
- Ergonomic design, low center of gravity and rubber surface for the perfect handling.
- V-groove in the probe holder for positioning on curved parts
- Graphic display with flipping measuring presentation view – 0°, 90°, 180°, 270°.
- Ready to measure, No need for calibration adjustment for most applications.
- Built-in temperature compensation for improved measurement accuracy.
- Calibration certificate showing traceability to Physikalisch Technische Bundesanstalt (PTB)- German equivalent to NIST in the US.
- Gauge body Built-in Software for statistical evaluation for process control with the QN 9500 PC software.
- Define Limits- Pass/Fall warning per RGB LED on probe - Premium & Premium plus only.
- Duplex (Fe/NFe) and continuous measuring mode - Premium & Premium plus only.
- Multiple calibration adjustments options – Premium & Premium plus only.
- Batches for SSPC-PA 2, IMO PSPC, ISO 19840, Australian AS 3894.3 B, Swedish IS 18 41 60 preconfigured – Premium plus only.
Measuring duplex coatings with the QNix 9500 premium and premium plus versions: Paint/hot-dip galvanized coatings on steel are simultaneously measured -using a Dual probe, and their thicknesses are displayed separately.
ALL GAUGES FEATURE........Tough probes (IP65) & robust housing (IP64)
Waterproof-Solvent, acid, oil-resistant
Designed for rough manufacturing environments
German Engineering
Defense, Automotive, commercial & industrial products, medical equipment, shipbuilding, infrastructure, aerospace, offshore, chemical plants, production line testing/simply quality control checks out in the field, etc.
The Trueness Of Measurements:
QNix® 9500 - Accuracy of measurement on Fe substrates related to QNix® reference standards: (1 μm + 2 % of the reading) to 2,0 mm; 3 % of the reading from 2,0 mm
QNix® 9500 - Accuracy of measurement on NFe substrates related to QNix® reference standards: (2 μm + 2 % of the reading) to 2,0 mm; 3 % of the reading from 2,0 mmMeasuring Ranges Of The Available Probes Scope of Supply• Gauge body with built-in PC software QN9
• Fe- and NFe zero-reference plates and two test foils (shims)
• Certificate of Calibration traceable to PTB (only with integrated
measuring probe)
• Operation/User manual
• USB cable
• 2 Mignon batteries 1,5 V (AA) alkaline
• Plastic case for transportation and storage
Coat Scope-i(Integrated probe)(Fe & Nfe Combined)
Minimum Order Quantity: 1 Piece
Model | Metrix + Coat Scope-i(Integrated probe) |
International Standard | It meets the standards of both ISO2178 and ISO2361 as well as DIN, ASTM and BS. |
Display | 4 digits LCD, backlit |
Measuring range | 0-2000um/0-80mil |
Resolution | 0.1 um (0~99.9um); 1 um (over 100um) |
Accuracy | + 1-3%n or + 2.5 um |
Memory Store/Recall | Min/Max/Ave. 99 Group measurements |
Min. Radius work piece | NF: Convex 3 mm / Concave 50 mm |
Min. Measuring area | 6 mm |
Min. Sample thickness | 0.3mm |
Metric / Imperial | Selectable |
Selectable | Temp. 0~50oC ; Humidity <95% |
Battery indicator | Low battery indicator |
Standard Accessories | Probe (F/nF combine) '0' Calibration Blocks, Calibration Foils, Operation Manual & Hard Carry case |
Optional Accessories | Cable & Software, USB Cable & Software, Bluetooth data output, other |
Coat Scope-i(Integrated probe)(Fe & nfe Combined)
0-2000um/0-80mil
+ 1-3%n or + 2.5 um
Features: It can be used both in the laboratory and in harsh field conditions.
Performs two different method of calculating coating measurement by utilizing characteristic of both eddy current and magnetic induction both non-destructive and accurate.
Can measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminium , chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . Often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminium tile, some alloy tile, paper etc.
Can measure the thickness of non-magnetic Coatings on non-magnetic metals. it is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminium, brass, non-magnetic stainless steel, etc.
Unique Single probe Used to Measure Fe (ferrous) & nFe (non-ferrous) substrates.
Automatic substrate recognition. * Manual or automatic shut down. Two measurement mode: Single and Continuous * Wide measuring range and high resolution. * Metric/Imperial conversion. * Digital backlit display gives exact reading with no guessing or errors.
Malein/Ave reading *99 Measurement memory can be stored/Recall PC interface with optional RS 232C cable Software.
Additional Information:
- Delivery Time: Ready Stock (Subject to Prior Sales) OR 2 to 3 weeks