- Home
- »
- Our Product Range
- »
- Coating Thickness Gauge
Coating Thickness Gauge
Qnix 4500 Digital Coating Thickness Gauge
Minimum Order Quantity: 1 Piece
Product Brochure
| Measuring Range | 3000 Micron |
| Brand | QNix |
| Accuracy | 1 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 10 mm |
| Minimum Sample Thickness | 0.3 mm |
| Model Name / Number | 4500 |
| Type | F / NF |
| Principle of operation | Two magnetic measuring principle: Fe:Magnetic Flux / Hall Effect (Fe*) NFe: Eddy Current (NFe*) |
|||||||||||||||
| Standards | DIN EN ISO 2808, ISO 2178, ASTM B 499, ASTM D 7091, ISO 2360 | |||||||||||||||
| Probe Type | Integrated or - optional - with 1m cable | |||||||||||||||
| Measuring Range | Fe: 0,0–3000 μm | NFe: 0,0–3000 μm Fe: 0,0–3000 μm | NFe: 0,0–5000 μm |
|||||||||||||||
| Metric system μm/mil | Yes | |||||||||||||||
| Measuring Frequency | Single Measurement: 850 ms | |||||||||||||||
| Display Metric | from 0 to 999 in μm, from 1000- to 3000 in mm (1,00-5,00 mm) | |||||||||||||||
| Resolution | 0,1 μm in 0,0–999 μm range, 0,01 mm in 1,00-3,00 mm (1,00-5,00 mm) range |
|||||||||||||||
| Accuracy acc. to Automation Dr.Nix Standards |
|
|||||||||||||||
| Minimum measuring area | Ø 25 mm | |||||||||||||||
| Minimal Curvature | convex: 5 mm, concave: 25 mm | |||||||||||||||
| Minimal Substrate Thickness | Fe: 0,2 mm | NFe: 0,05 mm | |||||||||||||||
| Display | Digital LCD | |||||||||||||||
| Temperature Range | 0 – 50°C (32 – 122°F) | |||||||||||||||
| Permitted Storage Temperature | -10° C – 60°C (14 – 140°F) | |||||||||||||||
| Power Supply | 2 batteries 1,5 V (AA alcali) | |||||||||||||||
| Dimensions (L x W x H în mm) | 100 x 60 x 27 (with integrated probe) | |||||||||||||||
| Weight (inlc. batteries) | With Integrated Probe: 105 g With Probe with Cable: 147 g |
Elecoat C Coating Thickness Gauge
Minimum Order Quantity: 1 Piece
Product Brochure
| Measuring Range | 0 - 2000 um |
| Type | NF |
| Accuracy | 1 % of reading |
| Resolution | 1 um |
| Minimum Sample Thickness | 0.3 mm |
| Model Name / Number | Elecoat C |
- Resolution :- 0.1<20 Microns, 1>20 Microns
- Minimum Measuring Area :- 6mm, Working Temperature :- 10-50˚C
- Package included : 1 piece
- Dimension: 135x 70x 24millimeter
- Working Temperature :- 10-50˚C, Battery Supply Voltage/Type :- 9 Volts, (6F22)
LS221 Coating Thickness Gauge
Minimum Order Quantity: 1 Piece
Product Brochure
| Measuring Range | 3000 um |
| Accuracy | 3 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 25mm |
| Minimum Sample Thickness | 0.05 mm |
| Model Name / Number | LS221 Coating Thickness Gauge |
| Power Supply | 2 X 1.5 AAA batteries |
| Type | F / NF |
LS237 Coating thickness Guage
Minimum Order Quantity: 1 Piece
Product Brochure
| Measuring Range | 3000 um |
| Accuracy | 3 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 25mm |
| Minimum Sample Thickness | 0.2 mm |
| Model Name / Number | LS 237 Coating thickness Guage |
LS225 With F & N Probe Coating Thickness Gauge
Minimum Order Quantity: 1 Piece
Product Brochure
| Measuring Range | 500 um |
| Accuracy | 2% reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 7 mm |
| Model Name / Number | LS225 with F & N Probe Coating Thickness Gauge |
| Type | F / NF |
Qnix Coating Thickness Gauge 9500 FNF
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | QNix |
| Model Name / Number | 9500 FNF 1.2 mm |
| Type | F / NF |
| Measuring Range | 0 - 1250 um |
| Accuracy | 1 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 10 mm |
| Minimum Sample Thickness | 0.3 mm |
- Fibreglass reinforced, 5 piece casing with IP65 dust and splash water protection
- Three layer protection to absorb shocks
- LCD glass providing resistance against scratches and chemicals (Level H6)
- Operational temperature from -20 °C to +70 °C
MiniTest 650 B-F Coating Thickness Gauge Elektrophysik
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | Elektrophysik |
| Model Name / Number | MiniTest 650 B-F |
| Measuring Range | 0 - 3000 |
| Accuracy | 1 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 7 mm |
| Minimum Sample Thickness | 0.3 mm |
To measure non-magnetic coatings (varnishes, enamels, chromium etc.) on ferromagnetic substrates (e.g. steel used in construction and for auto body).
Measuring range 0 to 3 mm.
With preset measuring units µm or mils. Please specify while placing the order.
Enables 1-point calibrations.
Non-destructive coating thickness measurement:
- Non-magnetic coatings like varnishes, enamels, chrome and zinc on ferromagnetic base materials (e.g. steel)
- Insulating coatings like varnishes and anodising aluminium on non-ferrous metals (e.g. aluminium, copper, die-cast zinc)
- Magnetic induction (F-type sensors) according to DIN EN ESO 2808, method 7C
- Eddy current (N-type sensors) according to DIN EN ESO 2808, method 7D
- Gauge MiniTest 650 with fixed probe
- 3 batteries AAA / LR03 / Micro
- Control plate(s), calibration standards in folding case
- Operating manual on a CD
- Quick reference guide
- Factory certificate
- Soft case
MiniTest 650 B-FN Coating Thickness Gauge Elektrophysik
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | Elektrophysik |
| Model Name / Number | MiniTest 650 B-FN |
| Type | F / NF |
| Measuring Range | 0 - 2000 um |
| Accuracy | 1 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 7 mm |
| Minimum Sample Thickness | 0.2 mm |
MiniTest 650 B-FN
To measure non-magnetic coatings (varnishes, enamels etc.) on ferromagnetic substrates (e.g. steel used in construction and for auto body) and to measure insulating coatings (varnishes, enamels, anodic coatings etc.) on non-ferrous metals (aluminium, copper, brass etc.).
Measuring range 0 to 2 mm.
With preset measuring units µm or mils. Please specify while placing the order.
Enables 1-point calibrations.
Non-destructive coating thickness measurement:
Non-magnetic coatings like varnishes, enamels, chrome and zinc on ferromagnetic base materials (e.g. steel)
Insulating coatings like varnishes and anodising aluminium on non-ferrous metals (e.g. aluminium, copper, die-cast zinc)
Magnetic induction (F-type sensors) according to DIN EN ESO 2808, method 7C
Eddy current (N-type sensors) according to DIN EN ESO 2808, method 7D
Gauge MiniTest 650 with fixed probe
3 batteries AAA / LR03 / Micro
Control plate(s), calibration standards in folding case
Operating manual on a CD
Quick reference guide
Factory certificate
Soft case
Coating Thickness Gauge Electro Physik MiniTest 650FN
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | Elektrophysik |
| Model Name / Number | 650FN |
| Measuring Range | 0 - 2000 um |
| Accuracy | 3 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 5 mm |
| Minimum Sample Thickness | 0.3 mm |
| Power Supply | 3 x 1.5V AAA batteries |
Product DescriptionMiniTest 650
The rugged coating thickness gauge MiniTest 650 follows its long-time proven predecessor model MiniTest 600 in the line of gauges with a fixed external probe offering measurement of all non-magnetic coatings on steel and all insulating coatings on non-ferrous metals. It was especially designed to work in rough environments as well as on on abrasive surfaces, e.g. shot-blasted steel, plasma spray coated surfaces.
Applications
Non-destructive coating thickness measurement:
non-magnetic coatings, e.g. paint, enamel, chrome, zinc on ferromegnetic substrates (e.g. steel)
insulating coatings, e.g. paint, anodizing on non-ferrous metals (e.g. aluminium, copper)
Performance features
Coating thickness measurement up to 2 or 3 mm
Universal probe offering automatic identification of the substrate for quick measurements on steel and non-ferrous metals
Wear-resistant probe tips with practically unlimited durability
USB-interface to transfer measuring data to a PC
Statistical evaluation of readings
Models
MiniTest 650 F
for coating thickness measurement on ferro-magnetic substrate(steel)
maximum coating thickness 3 mm
MiniTest 650 N
for coating thickness measurement on conducting, non-ferrous substrate (non-ferrous metals, e.g. aluminium, copper, etc.)
maximum coating thickness 2 mm
MiniTest 650 FN
for coating thickness measurement on ferro-magnetic and non-ferrous substrates, automatic identification of substrate type
maximum coating thickness 2 mm
Measuring principle
Magnetic induction and eddy current principle according to ISO 2808
Qnix Coating Thickness Gauge
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | QNix |
| Model Name / Number | 4600 FNF 1.2 |
| Type | F / NF |
| Measuring Range | 0 - 1250 um |
| Accuracy | 1 % of reading |
| Resolution | 0.1 um |
| Minimum Measurement Area | 10 mm |
| Minimum Sample Thickness | 0.3 mm |
Coating Thickness Gauge
| Model Name/Number | CM-1210 |
| Brand | Landtek |
| Measuring Range | 0 to 2000 microns |
| Material | ferrous & Non ferrous Metal |
| Display | Digital |
| Type | Portable |
| Display Type | Digital |
| Accuracy | +-1 to 3% n or +-2.5 microns |
| Weight | 215g(Not Including Batteries) |
* Can store the new data in 99 groups.
* Two measuring methods: magnetic induction (F) and eddy current (N)
* Two measurement mode: Single and Continuous Notice Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Automatic memory of calibration value,and automatic recognize the substrate.
* Operation process have buzzing reminder,while no buzzing in continuous mode.
| Principles | Applications | Examples |
| F Type Magnetic Induction (Iron Base) | Measure the thickness of non-magnetic materials on magnetic materials | Galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminium tile, some alloy tile, paper etc |
| NF Type Eddy Current (Aluminium Base) | Measure the thickness of non-conductive coatings on non-magnetic metals | Anodizing, varnish, paint, enamel, plastic coatings, powder, etc. Applied to aluminum, brass, non-magnetic stainless steel, etc |
Specification :
| Principle | F Magnetic Induction & NF Type Eddy Current |
| Range | 0~2000µm/0~80mil |
| Resolution | 0.1µm/1µm |
| Accuracy | ±1~3%n or ±2.5µm |
| Min.Radius Workpiece | F Type:convex 1.5mm/concave 25mm |
| NF Type:convex 3mm/concave 50mm | |
| Min.Measuring Area | 6mm |
| Min.Sample Thickness | 0.3mm |
| Metric/Imperial | √ |
| Functions | Battery Indicator & Automatic Power Off |
| Data Memory | 99 Groups |
| Operating Conditions | Temperature:0~40ºC |
| Humidity:10~90%RH | |
| Power Supply | 4x1.5V AAA (UM-4)Battery |
| Dimensions | 140x72x34mm |
| Weight | 215g(Not Including Batteries) |
| Standard Accessories | CM-1210A | CM-1210B |
| Main Unit | √ | √ |
| Probe (F & NF Type) | √ | √ |
| Calibration Base (F) | √ | √ |
| Calibration Base (NF) | √ | √ |
| Calibration Foils | 1 set, 5 pieces | |
| Carrying Case | B04 | |
| Operation Manual | √ | |
Coating Thickness Tester (DFT Meter) With External Probes
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | MEXTECH |
| Model Name / Number | CM-801E |
| Type | F / NF |
| Measuring Range | 0~1350 um |
| Accuracy | +-2.5 um |
| Resolution | +-2~3%n or +-2.5um |
| Minimum Measurement Area | 6 mm |
| Minimum Sample Thickness | 0.3 mm |
Ferrous & Non-ferrous combine meter. Separate Probe type.
Features
* Two measuring methods: magnetic induction (F) and eddy current (N)
* Two measurement mode: Single and Continuous
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Automatic memory of calibration value, and automatic recognize the substrate.
* Operation process have buzzing reminder, while no buzzing in continuous mode.
* Separate Type can provide several types of probes,
* LCD value auto reverse
MEXTECH 0-1350 Micron Coating Thickness Meter
Minimum Order Quantity: 1 Piece
| Brand | MEXTECH |
| Model Name / Number | CM-801 |
| Type | F / NF |
| Measuring Range | 0 - 1350 um |
| Accuracy | +/- 2 - 3% |
| Resolution | 0.1 / 1 um |
| Minimum Measurement Area | 6 mm |
| Minimum Sample Thickness | 0.3 mm |
| Size | 115x57x26mm |
| Color | Blue |
| Power Supply | 2 X 1.5 AAA batteries |
| Operating Temperatures | 115x57x26mm |
Features
* Two measuring methods: magnetic induction (F) and eddy current (N)
* Two measurement mode: Single and Continuous
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Automatic memory of calibration value, and automatic recognize the substrate.
* Operation process have buzzing reminder, while no buzzing in continuous mode.
* Integral Type have better stability and repeatability.
* LCD value auto reverse